Request Foods
Holland, MI – their high-capacity convenience foods operation generates around 1 MGD of wastewater with TSS levels of 1,000 mg/L and FOG at 400 mg/L. A Dissolved Air Flotation pre-treatment system was installed to meet discharge requirements.
Odor was of particular concern, so FRC supplied DAF covers so vented gasses are directed into an odor scrubber system.
Solution Provided
- (2) F8 Flocculators
- (2) PCL 45 DAF Units
- Engineering
- Controls
- Non Gas-Tight DAF Covers